±¤ÇÐDO Controller (Optical DO) MOD3500
¼³¸í

Panel/Pipe/Wall mount type
0/4~20mA, on/off Á¦¾î
RS485Åë½Å ¹× MODBUSÁö¿ø

 

 
 
 

DO(mg/l, ppm)/Air(%)/¿Âµµ µ¿½Ã ÃøÁ¤
±¤ÇÐ ÃøÁ¤¹æ½ÄÀÇ DO¼¾¼­·Î ÀüÇØÁú¿ë¾×, ¸âºê·¹ÀÎ ±³Ã¼ ÇÊ¿ä ¾øÀ½
»ê¼Ò ¼Ò¸ð°¡ ÇÊ¿ä ¾øÀ¸¸ç, À¯¼Ó ¹× ±³¹ÝÀÌ ¾øÀ̵µ Á¤È®µµ ³ôÀº ÃøÁ¤
½Å·ÚÇÒ ¼ö ÀÖ´Â ¸ð´ÏÅ͸µ ¹× Microprocessor Á¦¾î ÄÁÆ®·Ñ·¯
Å« LCDÈ­¸éÀ¸·Î ÀÛµ¿»óÅ ¹× °£´ÜÇÑ ºÎÈ£ È­¸éÇ¥½Ã
Á¤¼ö¹°¿¡¼­µµ ÃøÁ¤ÀÌ °¡´É
»ó.ÇÏÇÑ ¼³Á¤, ON/OFF Á¦¾î ¹× ¾Ë¸² Ç¥½Ã
¼¿ÇÁŬ¸®´× ¼¾¼­ ±â´É µ¿ÀÛ(ÇÁ·Î±×·¥ ¼¼ÆÃ)
ÀÚµ¿,¼öµ¿ º¸Á¤, ¿Âµµº¸»ó
Solution-graound ±â´ÉÀ¸·Î »ùÇà °£¼· ÃÖ¼ÒÈ­
±âº» 0/4~20mA ¾Æ³¯·Î±× Ãâ·Â ¹× RS485(MODBUS) Åë½ÅÃâ·Â Á¦°ø
LED °æº¸ Ç¥½Ã ÀÛµ¿À¸·Î ºü¸¥ µ¿ÀÛ ÀÎ½Ä °¡´É
º®/ÆгÎ/ÆÄÀÌÇÁ ¼³Ä¡¿¡ ÀûÇÕÇÑ ½Ç¿Ü ¹æ¼ö¼³°è (IP65)
144 x 144 x 155 mm 


* Àû¿ëó : °­¹° / ¹Ù´å¹° / Á¤¼ö¹° / Çϼöó¸®Àå µî °¢Á¾ ¼öÁúÀÇ DO ÃøÁ¤¿¡ »ç¿ë

 

 * Controller
 

±â±â ¸ðµ¨

MOD3500

ÃøÁ¤Ç׸ñ

DO(mg/l, ppm) / Air(%) / Temp.

ÃøÁ¤¹üÀ§

DO : 0.00~19.99 mg/l (ppm)
Air : 0~200%
Temp. : -30~130¡É (¼¾¼­¿¡ µû¶ó ´Ù¸§)

ºÐÇØ´É

DO : 0.01 mg/l   /   Air : 0.01 %  /  Temp. : 0.1¡É

Á¤È®µµ

DO : ¡¾3% ¡¾1digit  /  Temp. : ¡¾0.2¡É ¡¾1digit, ¿Âµµ ¿ÀÂ÷ º¸Á¤±â´É Æ÷ÇÔ

¾Ð·Â¹üÀ§

0.500~2.500 bar (7.25~36.25 psi)

¿°µµº¸»ó

0.0~45.0 ppt

¿Âµµº¸»ó

ÀÚµ¿ ¿Âµµ º¸»ó

µð½ºÇ÷¹ÀÌ

LCD µð½ºÇ÷¹ÀÌ, ÀÚµ¿ ¹é¶óÀÌÆ® ¼±ÅÃ

¾Æ³¯·Î±× Ãâ·Â

Isolated DC 0/4~20mA corresponding to measurement, max load 500¥Ø

½Ã¸®¾ó ÀÎÅÍÆäÀ̽º

RS-485(MODBUS RTU)

¼ÂÆÃ

Contact

RELAY ON/OFF Á¢Á¡£¬240VAC 0.5A Max.

Activate

Two sets Hi/Lo programmable, ON/OFF

¼¼Ã´

Á¢Á¡Á¦¾îÃâ·Â£¬ON 0~9999ÃÊ / OFF 0~999.9½Ã°£

µðÁöÅÐ ÇÊÅ͸µ

0~60ÃÊ (±âº» ¼³Á¤°ª 30ÃÊ)

¹æ¼öµî±Þ

IP65/ NEMA 4

Àü¿ø

100~240VAC ¡¾10%, 50/60Hz

¼³Ä¡¹æ½Ä

º® / ÆÄÀÌÇÁ / ÆгÎ

Å©±â

144 mm x 144 mm x 115 mm (H x W x D)

Cut Off Ä¡¼ö

138 mm x 138 mm (H x W)

¹«°Ô

0.8Kg


* Sensor 

 

¼¾¼­ ¸ðµ¨

Optical DO MD1900

ÃøÁ¤¹æ½Ä

Çü±¤ ÃøÁ¤¹æ½Ä (Optical)

ÃøÁ¤¹üÀ§

DO : 0~20mg/l(ppm) / Air : 0~200%

Á¤È®µµ

¡¾ 0.5% FS

»ç¿ë ¾Ð·Â

0.6MPa (6 bar)

¼¾¼­ ÀÀ´ä ½Ã°£

90% <60ÃÊ (at 25¡É)

¼¾¼­ Å©±â/¹«°Ô

¨ª50.6 x 260 mm / 1.36 kg

ÀçÁú

¼¾¼­ : SUS316L ºí·¢ ƼŸ´½ /  ĸ : POM / ¸âºê·¹ÀÎ : Çü±¤¸·½Ç¸®ÄÜ

Ä¿³ØÅÍ ¿¬°á ³ª»ç

G1 ±Ô°Ý

¼¾¼­ ÄÉÀÌºí ±æÀÌ

10m ÄÉÀÌºí ±âº» (ÃÖ´ë 80m ±îÁö ¿É¼Ç °¡´É)

 

 

 

(1) Standard
​   - ±â±â º»Ã¼
   - »ç¿ë¼³¸í¼­

 (2) Options
   [¼¾¼­ ¹× ¼Ò¸ðÇ°]
   - Optical DO sensor with 10m cable
   - Optical DO membrane cap

   [±âŸ]
   - Sensor Holder & Bracket or Flange (SUS / PP / PVC)
   - Panel (SUS / ABS / PC)
   - Áß°è¹Ú½º & ¿¬ÀåÄÉÀ̺í
   - ISCP PC¿¬°á¿ë ÇÁ·Î±×·¥ CD & RS485 to USB ÄÁ¹öÅÍ ​(PC¿¬°á½Ã ÇÊ¿ä)